| Splicing Method | Core Alignment AOCAT(Automatic Optical Core Analysis & Tracking System) |
| Average Loss | SM(0.02dB) / MM(0.01dB) / DS(0.04dB) / NZDS(0.04dB) / G.657(0.02dB) |
| Return Loss | >>60dB |
| Splice Time | 10s average SM / SM 7s Quick mode |
| Electrodve Lifespan Applicable Fiber Cleaved Length | >5,500 arcs SM(ITU-T G.652&G.657), MM(ITU-T G.651), DS(ITU-T G.653), NZDS(ITU-T G.655), IT-G657A, IT-G657B / 0.25mm, 0.9mm, 2.0mm, 2.4mm, 3.0mm, FLAT(indoor cable) Coating Diameter < 0.25mm = 8-16mm, Coating Diameter > 0.25mm = 16mm minimum |
| Coating Diameter | 100-1,000um |
| Cladding Diameter | 80-150um |
| Heating Programs | Factory installed mode : 11, User installable mode : 23 |
| Heating Time | Typical 15s |
| Protection Sleeve | 40mm, 60mm, SOC Connector |
| Data Output | Micro HDMI-USB master device |
| Splice Programs | Factory installed mode: 33, User installable mode: 70+ |
| Splice Memory | Up to 5,000 records and 2,000 splice images |
| Illumination | LED emitting white light (1 piece) |
| Battery | Typical 200 Cycles (Splice & Heat) / single battery <2 Batteries Standard> |
| Power Supply | AC 100-240V input or DC 9~14V |
| Monitor | Color 4.3’’ LCD monitor, with Touch Screen (Tempered Glass) |
| Cameras Magnification Fiber Display | 2 CCD camera system XY style : 150 power, X/Y : 300 power X/Y or XY, single X.Y |
| Weight | 1.49Kg (without battery) |
| Size | 122mm X 124mm X 138 mm |
| Wind Protection | The max wind speed 15m/s |
| Operating Environment | Elevation 0-5,000 meters, -20~60˚C, 0~95% relative humidity |
| Storage Condition | Temperature -20 to 40˚C, 0~95% relative humidity, battery -20~30˚C |
| Pull Test | 1.96~2.25N (standard) |
| Attenuation splicing | Range : 0.1dB ~ 20dB (0.1dB step) |