Splicing
Method |
Core Alignment AOCAT(Automatic
Optical Core Analysis & Tracking System) |
Average
Loss |
SM(0.02dB) / MM(0.01dB) /
DS(0.04dB) / NZDS(0.04dB) / G.657(0.02dB) |
Return
Loss |
>>60dB |
Splice
Time |
10s average SM / SM 7s Quick
mode |
Electrodve
Lifespan Applicable Fiber Cleaved Length |
>5,500 arcs SM(ITU-T
G.652&G.657), MM(ITU-T G.651), DS(ITU-T G.653), NZDS(ITU-T G.655),
IT-G657A, IT-G657B / 0.25mm, 0.9mm, 2.0mm, 2.4mm, 3.0mm, FLAT(indoor cable)
Coating Diameter < 0.25mm = 8-16mm, Coating Diameter > 0.25mm = 16mm
minimum |
Coating
Diameter |
100-1,000um |
Cladding
Diameter |
80-150um |
Heating
Programs |
Factory installed mode : 11,
User installable mode : 23 |
Heating
Time |
Typical 15s |
Protection
Sleeve |
40mm, 60mm, SOC Connector |
Data
Output |
Micro HDMI-USB master
device |
Splice
Programs |
Factory installed mode: 33, User
installable mode: 70+ |
Splice
Memory |
Up to 5,000 records and 2,000
splice images |
Illumination |
LED emitting white light (1
piece) |
Battery |
Typical 200 Cycles (Splice &
Heat) / single battery <2 Batteries Standard> |
Power
Supply |
AC 100-240V input or DC
9~14V |
Monitor |
Color 4.3’’ LCD monitor, with
Touch Screen (Tempered Glass) |
Cameras
Magnification Fiber Display |
2 CCD camera system XY style :
150 power, X/Y : 300 power X/Y or XY, single X.Y |
Weight |
1.49Kg (without battery) |
Size |
122mm X 124mm X 138 mm |
Wind
Protection |
The max wind speed 15m/s |
Operating
Environment |
Elevation 0-5,000 meters,
-20~60˚C, 0~95% relative humidity |
Storage
Condition |
Temperature -20 to 40˚C, 0~95%
relative humidity, battery -20~30˚C |
Pull
Test |
1.96~2.25N (standard) |
Attenuation
splicing |
Range : 0.1dB ~ 20dB (0.1dB
step) |